Optimizing the system, Injectors vs. metering tips vs. nozzles, Istobal m22 / m24 initial set up – Hydra-Flex Aqua-Lab EVO User Manual User Manual

Page 8

Advertising
background image

© Hydra-Flex Inc 2014

Page | 6

Istobal M22 / M24 Initial Set Up


Application

Injector

Nozzles

Pre Spray / 2 step

618098 – 3.25gpm

10x 0880, 4x 632.676

Shampoo

618086 – 2.25gpm

2x 0880, 10x 0680

Shampoo Rinse

Flow Thru - 3000173

See shampoo

White Foam

618086 – 2.25gpm

As Shipped

Triple Foam

3x 618070 – 1.5gpm each

As Shipped

Wax / Super Wax

618096 – 3.25gpm

2x 632.676, 2x0880

Horns Rinse

Flow Thru - 3000173

See Wax

Low Pressure Under Spray Flow Thru - 3000173

As Shipped

CTA

TBD

TBD

Bug Spray

TBD

TBD






Optimizing the System

Consistently achieve the desired cleaning and presentation/performance

using the least amount of chemical and water

Injectors vs. Metering Tips vs. Nozzles

The key to optimizing the system is through trial and error.

Don’t be afraid to try these steps to achieve your ideal performance.

What do injectors do?

o Increases or decreases the amount of water

in the solution

What do metering tips do?

o Increases or decreases the amount of

chemical in the solution

What do nozzles do?

o Determines the pattern and backpressure of

the solution





Advertising