To determine the frequency of regeneration, use this procedure:

Setting the Frequency of Automatic Regeneration (SXT Models)

Please enter the ppm of compensated iron per gallon of water to be removed. See Step #4 of “User
Programming.” The SXT valve will automatically calculate the number of gallons of water to be treated by the
iron filter between regenerations.

Iron Content in the Feed Water:

ppm of capacity between regenerations (see Specifications - Page 1)

÷ ppm of iron in the water sample*
= number of gallons supplied between regenerations
- reserve capacity (number of people x 75 gallons)

Example - Using 5600 SXTM-948IF + 1 Feeder

6000

ppm between regenerations

÷

8

ppm of compensated iron [To be entered by the user]

=

750

gallons between regenerations [See step #5 of “User Programming”]

375

gallons reserve capacity (5 people x 75 gallons)

=

375

GALLONS - BETWEEN REGENERATIONS [Calculated by valve]

* 1 ppm of manganese = 2 ppm of iron; 1 ppm of hydrogen sulfide = 3 ppm of iron

Days:

Total amount of iron to be removed between regenerations -

÷ ppm of iron to be removed per day
= NUMBER OF DAYS BETWEEN REGENERATIONS

Example:

5

people in the household

x

75

gallons of filtered water per person

=

375

gallons of filtered per day

x

8

ppm of compensated iron

=

3,000

PPM OF IRON TO BE REMOVED PER DAY

Using 5600 SXTM-948IF + 1 Feeder

6,000

ppm capacity

÷

3,000

ppm to be removed per day

=

2**

DAYS BETWEEN REGENERATIONS

**Maximum number of days between regenerartions should be 12.