How your 5600sxt water filter works, Performance and specifications – Hydrotech 5600 SXT Valve Iron & Sulfur Filter Operation Manual User Manual

Page 3

Advertising
background image

How Your 5600SXT Water Filter Works

Your automatic iron filter is an ingeniously simple and reliable design. The unit consists of a bed of filter media contained
in a fiberglass tank; a specially designed feeder containing potassium permanganate for the regeneration of the filter
and a proven automatic control.

Raw water enters your home through the main supply line, enters your iron filter and passes down through the filter
media. Any iron, manganese or hydrogen sulfide present in your water supply is exposed to oxygen stored in the filter
media. The oxygen causes precipitation of the minerals and they are trapped in the filter media. Only clean filtered water
flows to your household water line. The filter media is periodically regenerated, automatically backwashing the trapped
minerals to the drain and replacing the oxygen. This is done by introducing potassium permanganate to the media.

1. Your automatic iron filter can be programmed to operate according to your needs by making the appropriate settings

on the timer. On the days your filter regenerates, the operating cycles will be automatically performed. In the service
position, filtered water is supplied for household use.

2. The automatic control reverses the flow of the water through the filter, backwashing minerals trapped in the filter to

the drain.

3. The control pulls a vacuum on the feeder. This causes an exact volume of saturated potassium permanganate

solution to be drawn into the filter tank.

4. The control slowly rinses the chemical through the media tank. The potassium permanganate supplies oxygen to the

filter media.

5.

The control fast rinses the media bed to settle it and to ensure that all the chemical and mineral precipitate is
removed.

6. The control adds water to entirely fill the previously evacuated feeder. The feeder is now ready for the next

regeneration. The control puts the system into service, supplying iron-free water to the household. All this is
performed automatically over a period of 2 ¾ hours. Water runs to the drain for approximately 80 minutes.

1

Performance and Specifications

Item

Model

Pipe

Max. Bed

Iron removal

Service

Peak

Backwash

Mineral

KMnO

4

Shipping

Number

Number

Media

Size

Capacity

Capacity

Flow Rate

Flow Rate

Flow Rate

Tank size

Regeneration

Weight

cu. ft. (litres)

inches (mm)

(ppm)

(ppm)

USGPM (LPM)

inches (mm)

(oz)

Lbs. (kg)

7621

5600SXTM-847IF

0.75 (21)

3/4 (19)

6000

4500

3.0 (7.6)

4.0 (15)

3.5 (13)

8 x 47 (203 x 1194)

2

120 (55)

7622

5600SXTM-948IF

1.00 (28)

3/4 (19)

8000

6000

3.0 (11)

5.0 (19)

4.0 (15)

9 x 48 (229 x 1219)

4

135 (61)

7623

5600SXTM-1054IF

1.50 (42)

3/4 (19)

12000

9000

5.0 (19)

8.0 (30)

5.0 (19)

10 x 54 (254 x 1372)

6

185 (84)

Hydrotech Iron & Sulfur (Manganese Greensand) Filter

Notes:
Operating Temperature Range:
34° to 110°F (1° to 43°C)
Operating Pressure Range: 20 to 120psi (137 to 827 kPa)
Electrical: 24V/60Hz with a supplied 120V/60Hz Wall Mount CSA Approved Transformer

1. The manufacturer reserves the right to make product improvements which deviate from the

specifications and descriptions stated herein without obligation to change previously manufactured
products or to note the change.

2. Peak flow rates are intended for intermittent use only and are for residential application only.
3. KMnO

4

refers to Potassium Permanganate.

Caution: These water conditioners are not intended to be used for treating water that is microbiologically unsafe or of unknown quality without adequate
disinfection before or after the system.

In normal operation, the Time of Day display will alternate being viewed with the Volume Remaining display. This display
will be in gallons, liters or cubic meters. As treated water is used, the Volume Remaining display will count down from a
maximum value to zero or (---). Once this occurs, a regeneration cycle will be initiated at the Set Regeneration Time. Water
flow through the valve is indicated by the Flow Indicator that will flash in direct relationship to flow rate.

Example

833 Gallons of Treated
Water Remaining

0 Gallons of Treated
Water Remaining

PM Indicator

PM Indicator

Flow Indicator
(Flashing with water flow)

Flow Indicator
(Flashing with water flow)

Advertising