Operating Instructions

Water Pressure

Your water filter is designed to operate under normal water pressures from 20 psi to 100 psi.

Regeneration and Automatic bypass

Water filters are factory set to regenerate at 11:00 p.m. during a period of little or no water use. The regeneration cycle

lasts approximately 15 minutes, after which filtered water service is restored. While regeneration is taking place,”raw

water” automatically bypasses the filter if required. If possible, avoid using water during regeneration to prevent

unfiltered water entering your household plumbing system.

(Installation Tip: The 5600SXT Filter should not be allowed to regenerate at the same time as any other water

treatment units. If adjustment is required, consult programming chart to adjust default regeneration time.)

New Sounds

You will notice new sounds such as the hum of the timer, as your filter operates. During regeneration, it will not be

uncommon to hear water running to the drain.

Manual bypass

In case of an emergency you can isolate your water filter from the water

supply using the bypass valve located at the back of the control.
In normal operation the bypass is open with the ON/OFF knobs in line with

the INLET and OUTLET pipes. To isolate the filter, simply rotate the knobs

clockwise (as indicated by the word BYPASS and arrow) until they lock.
You can use your water related fixtures and appliances as the water supply

is bypassing the filter. However, the water you use will be untreated.
To resume filter water service, open the bypass valve by rotating the knobs

counter-clockwise.

Manual Regeneration Cycle

If you run out of filtered water because of inadequate regeneration frequency, inadequate reserve capacity, power failure

or unusually high water usage, you can initiate a manual regeneration simply by pressing the extra cycle button. The

filter will now automatically complete a regeneration cycle and return to service. If possible, avoid water use during the

regeneration cycle.
Once you have set your filter and you experience frequent loss of water pressure, you may have to increase the

frequency of regeneration by resetting the gallons between regeneration.

OUTLET

INLET

Start-Up Instructions

Water-only backwash

1. Check that the correct backwash (BW) flowrate has been determined based on the water temperature. (See table below)
2. Allow the tank to slowly fill with water from the bottom. This is most easily accomplished by setting the control valve to the backwash

position and partially opening the inlet valve until water flows from the drain line.

3. Allow the media to soak for at least 30 minutes.
4. Fully open the inlet valve and set the control valve in the backwash position.
5. Depending on how critical the application is, allow the filter to backwash for 20 to 30 minutes. Continue the backwash until the water
is clear and free of particles. This is backwash #1.
6. Allow the filter to settle for 10 to 15 minutes. Do not allow the control valve to enter the fast rinse cycle.
7. Depending on how critical the application is, allow the filter to backwash again for 15 to 20 minutes. This is backwash #2.
8. Allow the filter to fast rinse (downflow) for 5 to 8 minutes.
9. The filter is now ready for service.

Tank Diameter

8"

10"

12"

14"

16"

Reference

gpm@80°F

8

12

18

24

24

23 gpm/ft2

gpm@70°F

7

11

16

21

21

20 gpm/ft2

gpm@60°F

6

9

13

18

18

17 gpm/ft2

gpm@50°F

5

8

12

16

16

15 gpm/ft2

gpm@40°F

4

7

10

13

13

13 gpm/ft2

backwash Rate