13. Press once more to advance to the “4” Brine refill
position. Wait until the water level reaches 6” in
the brine tank. Water can be added to the tank to
speed up the filling but the valve should be in the
Brine Refill position for a minimum of two minutes to
purge the air out of the injector set.
Rapid Rinse Position
Brine Refill Position
Hard Water
Soft Water
To Drain
Hard Water
Soft Water
To Drain
Hard Water
Soft Water
To Drain
Hard Water
Soft Water
To Drain
Hard Water
Soft Water
To Drain
Hard Water
Soft Water
To Drain
RR
10
BF
12
14. Press to advance the valve from the Brine Fill position through service to the “1” position Brine/
Rinse position. Verify that water is being drawn from the tank. If not, repeat step 9.
15. Press button to advance the valve to the “2” Backwash position
16. Press to advance the valve to the “3” Rapid Rinse position
17. Press to advance the valve to the “4” Brine Fill position until there is 6” of water in the brine tank.
Press to advance the valve back into the service position indicated by the in upper left corner
of the display.