Aiphone NE-SS-1G User Manual

Vandal and weather resistant 1-gang sub station

Advertising
background image

+

-

- INSTRUCTIONS -

The NE-SS-1G is a 1-gang vandal proof and weather resistant sub stations designed for use with the NEM, NDR and
NDRM systems. This unit is constructed of 12 gauge stainless steel and is equipped with an option for an external output
contact closure when the sub station places a call (relay required). The unit either flush mounts into a 1-gang box, or
surface mounts with the SBX-SS-1G. Each unit includes tamper proof screws and a tool for installation.

WIRING DIAGRAM:

Vandal and Weather Resistant 1-Gang Sub Station

1
2
3
~

20

E

+

-

H

Red

Blk

Blu

Red

Blk

Blu

Pur

NEM Master

NE-SS-1G

NE-SS-1G

(w/dry closure output)

PS-2420UL

RY-PA

Blk

Blk

Yel

Dry closure

output for

duration of call-in

Red

Blk

Blu

NE-SS-1G

(w/corridor lamp)

Blu
Blu

NBY-4A

INSTALLATION:

1. For flush mounting, install sub station in standard 1-gang electrical box with min. 2-1/2" depth.
2. For surface mounting, install sub station in the SBX-SS-1G surface mount enclosure.
3. IMPORTANT! This unit is designed for use in normal weather conditions, and is made to allow for drainage and

evaporation of moisture that naturally gets into it. Do not apply caulking or silicone sealant around the unit
when installing, and do not use weather stripping around the perimeter of the box when mounting.

If

sealing the unit is required, the bottom must remain unsealed. Sealing the unit will prevent or inhibit moisture from
dissipating from inside the unit, which may cause corrosion or deterioration to the internal components over time.
Warranty does not cover damage caused by sealing the unit.

Page 1

WIRE DESIGNATIONS:
Red: + side of speaker. Connect to station number on master station.
Blue: Trigger for corridor lamp. 7V DC when call-in signal is activated.
Black: - side of speaker (common). Connect to E on master station.
Purple: Negative trigger wire for extra relay contact closure at sub during call-in.

Small wht & blk: Speaker connection to PCB
Small brn (x2): Call button connection to PCB

Back View

2-⅞” 3-¼”

1- ⁄ ”

15

16

NE-SS-1G

SPEAKER

CALL BUTTON WITH

CALL ASSURANCE LED

Advertising