In normal operation, the Time of Day display will alternate being viewed with the Volume Remaining display. This display
will be in gallons. As treated water is used, the Volume Remaining display will count down from a maximum value to zero
or (---). Once this occurs, a regeneration cycle will be initiated at the Set Regeneration Time. Water flow through the valve
is indicated by the Flow Dot that will flash in direct relationship to flow rate.
Example
833 Gallons of Treated
Water Remaining
0 Gallons of Treated
Water Remaining
In regeneration, the control will display a special regeneration display. In this display, the control will show the current
regeneration step number the valve is advancing to or has reached and the time remaining in that step. The step
number displayed will flash until the valve has completed driving into this regeneration step position. Once all
regeneration steps have been completed, the valve will return to Service and resume normal operation.
Example
Less than 6 minutes
remaining in Regen
Step #1
Pushing the Extra Cycle Button during a regeneration cycle will immediately advance the valve to the next cycle step
position and resume normal step timing.
Control Operation During Programming
The control will only enter the Program Mode with the valve in Service. While in the Program Mode, the control will
continue to operate normally, monitoring water usage and keeping all displays up to date. Control programming is stored
in memory permanently, eliminating the need for battery back-up power.
Control Operation During a Power Failure
During a power failure, all control displays and programming will be stored for use upon power re-application. The
control will retain these values for years, if necessary, without loss. The control will be fully inoperative and any calls for
regeneration will be delayed. The control will, upon power re-application, resume normal operation from the point where
it was interrupted. An indication that a power outage has occurred will be an inaccurate Time of Day display.