Non-isolated mode

To cause an input to detect an active signal in non-isolated mode, the
current must flow from the relevant input pin.

The external device should draw no current to cause an inactive input and
at least 5 mA to cause an active input. The opto-isolator drive line contains
a 1.5 kOhm resistor to limit the current through the opto-isolator. Therefore
the input pins can be connected directly to a ground pin to cause an active
input.

The voltage level at the external input pin should not be allowed to go below
ground or above +6 V with respect to ground.

Figure 18: Non-isolated mode

Figure 19: Pin configuration of the General Inputs connector