2 connecting the cpu card, 3 connecting interface cards, Connecting the cpu card – Clear-Com HX System Frames User Manual

Page 69: Connecting interface cards

Advertising
background image


5.8.2 Connecting the CPU Card

The rear-connector panel associated with the CPU card holds seven connectors

Tip:

For a detailed description of each connector, including wiring and pinout information,

see 4.7.1

CPU card interface connectors

.

A matrix only requires one rear-panel CPU card, because whichever of the two front-
installed CPU cards is acting as master will work in conjunction with this card. All other front
cards, however, require their own rear-connector panel.

Tip:

For detailed information about connecting the matrix to panels, interfaces and other

devices, see 4

Installing the

Eclipse HX-Delta

5.8.3 Connecting interface cards

Each rear-connector panel associated with an MVX-A16 (analog) interface card holds the
sixteen RJ-45 connectors that connect the matrix to user panels, interface modules and
other intercom devices. Each front-installed MVX-A16 port card requires a corresponding
rear-connector panel. Blank panels cover unused slots.

Each port on the matrix can be located and identified by using the rear-panel numbering
grid:

• Port rows are numbered 1 through 16.

• Port columns are numbered 1 through 7.

• CPU card columns are numbered P1 and P2. (One rear panel operates with either of

the currently active CPU cards).

Tip:

A port can be identified precisely by identifying its card number and port number

on the card. For example, the ports on the first card are designated 1-1, 1-2, 1-3, 1-4,
and so on; the ports on the second card are designated 2-1, 2-2, 2-3, 2-4, and so on.

Each rear connector panel associated with an E-QUE interface holds eleven RJ-45 ports:

• Eight ports for connection to wireless equipment.

• Two ports for DECT sync.

• One port for LAN connections.

Each rear connector panel associated with an IVC-32 interface holds eleven RJ-45 ports:

• Eight ports for connection to E1/T1 equipment (not used).

• Two ports for DECT sync (not used).

• One port for LAN connections, used for IP-enabled V-Series panels and Concert soft-

panels.

69

Eclipse HX-Delta User Guide

Advertising
This manual is related to the following products: