Clear-Com Tempest900 User Manual

Page 2

Advertising
background image

Select a location for the

BaseStation and/or Remote Transceiver

1

2

System range and performance may be greatly reduced if antennas are blocked

or obstructed.

●

Always operate the system with antenna attached, locate as high as possible
and away from all obstructions (especially metal).

●

Never use antenna on the back of the BaseStation when the BaseStation is
in a rack

●

When using the Whip (omni-directional) antenna, always locate it as close as
possible to the center of the coverage area.

●

When remotely locating antenna, use only high quality 50 ohm, low loss, RF
cable (30 ft max).

●

Remote antenna location of up to 1500 ft using standard CAT-5 wiring may be
achieved using the optional Tempest Remote Transceiver.

» This must be a point to point connection
» Plug your Transceiver into the BaseStation prior to powering ON the

BaseStation

●

Slide the battery door off by pressing down and back.

●

Install the battery or (3) AA batteries and replace the battery door.

●

Press and hold the ON/OFF button for two seconds; the BeltStation
will vibrate as it powers up.

●

Power the BeltStation OFF by pressing and holding the ON/OFF
button for four seconds.

●

Connect the AC power cord to the BaseStation and to the AC wall outlet.

●

Turn the BaseStation on via the front panel ON/OFF switch.

Power ON the BaseStation

Power ON the BeltStation

2 sec

POWER ON

4

From the front of the BaseStation, follow the steps below :
1. Press MENU (Main Menu)
2. Press 1 (BaseStation Settings).
3. Scroll to 7 (Tech Menu) and press ENTER. A Tech Menu warning

message will appear - Press ENTER to proceed.

4. Press ENTER or 1 (Radio Configuration).
5. Press ENTER or 1 (Network Number) and select a network other than

zero and press ENTER to save setting.

» If you have multiple BaseStations, ensure that you select a different

Network Number for each BaseStation.

» Collocated BaseStations should be in the same Network Number

Group.

6. Press MENU to return to previous menu; press 2 (Lockout Key) and

select a lockout key other than 255 and press ENTER to save setting.

7. Press MENU repeatedly until you get back to the Operational screen.
8. Power the BaseStation OFF; wait 10 seconds and power the BaseStation

ON again.

3

Changing the Default RF

Configuration

9

9

Tempest 900 operates in the 902 to 928 MHz frequency spectrum.

9

9

Tempest 900 MHz models should never be synced with 2.4 GHz models.

9

9

Tempest BaseStations and BeltStations are shipped with a default RF
configuration. It is highly recommended that you change your system from
the default to ensure proper RF performance especially in the presence of
other Tempest systems.

9

9

A BeltStation must be paired with a BaseStation for any communication to
take place. Pairing should be done AFTER the default RF configuration is
changed on the BaseStation.

9

9

Charge the BeltStation batteries prior to starting set-up.

Important things you need to know