Delete data, Send data to a printer or to a computer, Report output – Hach-Lange SENSION+ MM378 User Manual

Page 15

Advertising
background image

Option

Description

Electrode report

Electrode report—stores automatically the electrode
history and measurement conditions

Calibration data

Calibration data—stores automatically the current
calibration

Delete data

The entire measurement data or electrode report log can be deleted to
remove data that has already been sent to a printer or PC.

1. From the main menu use the or to select DATA LOGGER and

confirm.

2. Use the or to select Erase and confirm.
3. Use the or to select Measurement data or Electrode report and

confirm. Confirm again to delete the data.
The entire log is deleted at once.

Send data to a printer or to a computer

N O T I C E

The data output (printer or PC) needs to be selected first, so that the Print menu
is available (refer to

Select the data output

on page 13).

Note: Refer to

Report output

on page 15 to select the report output type.

1. From the main menu use the or to select DATA LOGGER and

confirm.

2. Use the or to select Print and confirm. Select one of the

following options and confirm with to print the data: Measurement
data, Electrode data, Calibration data, Calibration report or
Instrument condit.

Report output

N O T I C E

The data output (printer or PC) needs to be selected first, so that the Type of
report menu is available (refer to

Select the data output

on page 13).

Different report output types can be selected when a printer or a PC is
connected.

1. From the main menu use the or to select SYSTEM. Confirm.
2. Use the or to select Type of report and confirm.
3. When a printer or a computer and Terminal is connected, use the

or to select

Option

Description

Reduced Select Several or One sample as an output format

Standard Select Several or One sample as an output format. Select

several: Users: The user name appears on the printed report
(17 characters). Header:The company name can be added as a
header (40 characters) and appears on the print report. Identify
sensor:
The sensor model and the sensor serial number can be
added and appears on the print report.

GLP

Select Several or One sample as an output format. Select
several: Users: The user name appears on the printed report
(17 characters). Header:The company name can be added as a
header (40 characters) and appears on the print report. Identify
sensor:
The sensor model and the sensor serial number can be
added and appears on the print report.

4. When a computer is connected and LabCom Easy (refer to

Select

the data output

on page 13 for more information) is selected, use the

or to select

Option

Description

Users

The user name appears on the printed report
(17 characters).

Identify sensor The sensor model and the sensor serial number can be

added and appears on the print report.

English 15