INSTEON KeypadLinc Dimmer, 8 button (2486DWH8) Manual User Manual

Page 22

Advertising
background image

Page 22 of 24

Rev: 1/21/2014 7:36 AM

The controlled light does
not appear to turn on or
off right away

Responder’s Scene ramp
rate might be quite slow

Set a faster Ramp Rate – software
recommended

KeypadLinc responds to
on commands but not off
commands

Load connected to
KeypadLinc is producing
electrical noise that is
interfering with the
KeypadLinc reception of
power line signal

Install a

power line noise filter

between the

Load and KeypadLinc

Install additional INSTEON devices to boost
the INSTEON signal

My light only turns off
when I tap a button on
KeypadLinc, but I can
brighten and dim it

The On-Level may be set to
fully-off or very dim

Set a brighter On-Level. See

Setting the On-

Level

When I try to turn on my
light with another
Controller, the light turns
on, then back off

KeypadLinc may be set up
with an INSTEON On-Level
at a high brightness and an
X10 Primary or Scene
address On-Level at a low
brightness

Remove the X10 address

Remove the X10 address from the INSTEON
Controller

When I tap a button on
KeypadLinc, it takes a
long time for other
INSTEON devices it is
controlling to respond

KeypadLinc is trying to
control a Scene Responder
that is not powered on

If the INSTEON device is still available,
remove it from KeypadLinc or repower it

Perform a factory reset

KeypadLinc doesn't
respond to X10 address
A1 when I first set it up

KeypadLinc ships without an
X10 Address

Add an X10 address to desired button

I'm having difficulty
performing advanced X10
programming

The X10 "MNOP" house and
unit codes were sent in the
wrong order

Don’t hold down the buttons on your X10
Controller too long, to avoid duplicate codes
being sent

The Load is buzzing when
on or dim.

The dimming component
inside KeypadLinc "chops"
the power line sine wave to
reduce the power

The bulb filaments are vibrating. Use rough-
service, 130-volt, or appliance grade bulbs to
reduce the noise

Run KeypadLinc in the "full-on" mode or switch
to a non-dimming KeypadLinc On/Off (relay)
Switch

KeypadLinc is locked up

A surge or excessive noise
on the power line occurred

Pull the Set button on KeypadLinc all the way
out for 10 seconds to air-gap it, then tap back
in

Perform a factory reset

KeypadLinc is getting
warm to the touch

It is normal for wall dimmers
to get warm (KeypadLinc
conforms to Safety
standards)

KeypadLinc will dissipate about 1 Watt per 100
Watts controlled. Using metal junction boxes,
removing insulation around the outside of the
box, or controlling a smaller Load all will help
lessen the heat.

KeypadLinc can turn off
my Responder, but
nothing happens when I
send an On

Responder’s Scene level is
Off

Add Responder to Scene again at desired
Scene on-level