Installation – INSTEON Micro On/Off - 2443-222 (US), 2443-422 (EU), 2443-522 (AUS/NZ) Manual User Manual

Page 5

Advertising
background image

Page 5 of 21

2443-222/2443-422/2443-522 - Rev: 1/21/2014 8:28 AM

Installation

1)

Write down the INSTEON ID found on the back of the unit (XX.XX.XX)

2)

Turn off breaker/fuse and verify that the power is off

3)

Disconnect wires from existing switch, fixture or outlet and prep all wires to
be connected to Micro module, with 3/16” (5mm) of bare wire on the ends

4)

Connect wires per diagram which corresponds to your installation

Note: sense lines carry very low current (~0.35mA 240V, ~0.17mA for 120V)

5)

After ensuring wires are firmly connected and that there is no exposed wire, turn on breaker/fuse

After a few seconds, load will turn on (if wired into switch or fixture) and Micro module LED will turn green

6)

Test by tapping Micro module on/off buttons

Load will turn on and off
Micro Module LED will turn green when load is on and red when load is off

7)

If installing a single momentary or dual momentary switch
a) Press and hold set button until it beeps

LED will start blinking green

b) Press and hold set button until it beeps a second time

LED will start blinking red

c) Press and hold set button until it beeps a third time

LED will start blinking green

Advertising