Way toggle mode (latching switches only, default), Local control operation, Latching wall switch (default) – INSTEON Micro On/Off - 2443-222 (US), 2443-422 (EU), 2443-522 (AUS/NZ) Manual User Manual

Page 7

Advertising
background image

Page 7 of 21

2443-222/2443-422/2443-522 - Rev: 1/21/2014 8:28 AM

3) Press and hold Set button until it beeps a third time

LED will start blinking green

4) Slowly tap Set button six times

LED will continue blinking green

5) Press and hold Set button until it double-beeps

LED will stop blinking

6) Test mode change by tapping switch on and off

Load will respond appropriately

3-Way Toggle Mode (Latching Switches Only, Default)

Because Micro module comes programmed for latching switches, 3-way toggle mode is enabled by default.
Normally, a latching switch reads the switch’s up position as on and down position as off. For example, if you turn
Micro module on from the latching switch and off from another controller, the switch is still in the up (on) position;
turning Micro module back on from the switch would require you to tap the switch down, then up again.
The 3-way toggle mode overrides this sense feature, so in that same scenario—turning Micro module on at the
switch and off from another controller, so switch is in up (on) position—you could then turn Micro module on at the
switch by tapping it down.

If you are installing Micro module behind a single or dual momentary switch, 3-way toggle mode is ignored. If
desired, you can disable (or re-enable) 3-way toggle mode by following these instructions:

1) Press and hold Set button until it beeps

LED will start blinking green

2) Press and hold Set button until it beeps again

LED will start blinking red

3) Press and hold Set button until it beeps a third time

LED will start blinking green

4) Press and hold Set button until it beeps a fourth time

LED will start blinking red

5) Tap Set button

Micro module will beep and LED will start double-blinking red

6) Press and hold Set button until it double-beeps

LED will stop blinking
3-way toggle mode is now disabled (or re-enabled)

Local Control Operation

Micro module’s

switch operation mode

affects how it responds to commands from the switch. This is why it’s

important to program Micro module for the specific type of switch you are using. Micro module’s on/off buttons
function exactly like the top and bottom of your wall switch.

Latching Wall Switch (Default)

Note that this table refers to the latching switch operation if

3-way toggle mode

is disabled (it is enabled by default).










Connected load/responders

Latching switch

Tap

LED

Top

On

(ramped)

Green

Bottom

Off

(ramped)

Red

Advertising