LCD DISPLAY

DESCRIPTION

Action / Step 1:

Press POWER button ON

Displays Manufacturer.

Displays Degausser Model.

Displays current firmware version.

Displays total erasing cycles. Number on

left indicates number of times the counter

reached 50,000.

Ready for media to be placed in the Media

Entrance Door.

Counter for erase cycles from power up.

Indicates Media Entrance Door is open –

this Dis normal when inserting media to be

erased.

Action / Step 2:

Insert media

Media Entrance Door has closed and the

erase cycle has started.

Displays capacitor charging status.

Visual indicator of erasing field strength.

Indicates power and erasing field strength

was verified good and data has been elimi-

nated.

Action / Step 3:

Media gate has lowered and erased Media

will slide out.

OPERATION

Degaussing Overview

The LCD Display (2) gives status, automatic

count, total count, software version, field

strength, user instructions and fault messages.

The following information appears on the LCD

Display (2) from power-up through one automatic

degaussing cycle:

Automatic Degaussing Technical Detail

1) The LCD displays

“Insert Media Session =

0”.

2) The media to be degaussed is inserted into

the degaussing chamber through the Media

Entrance Door. While the media is sliding

into the degaussing chamber and the door is

open, the LCD will display

“Door Open”.

3) The media slides into the degaussing

chamber and stops when it contacts the

media gate.

4) Sensors in the Media Entrance Door

detect that media has been inserted and

automatically initiate the degaussing process

while displaying

“Erase Cycle Initiated” and

then displaying

“Charging >>>>>” on the

LCD Screen.

5) The LCD will display the Field Strength

Graph

“--------==I===”. The “I” in the graph

represents the strength of the erasing field.

The

“=====” portion of the graph represents

the normal range for field strength level. The

“I” within the “--------=====” indicates the

erase field strength. The position of the “

I

can vary from cycle to cycle as it is based on

the actual field strength.

6) If the field is in the normal range, the LCD will

display

“Data Eliminated”.

7) If the field is not in the normal range, the

LCD will display

“Erase Failure”. As an

added measure of security, the media will

remain inside the degaussing chamber until a

successful degauss is performed or until the

media is removed by following the instructions

in this manual under “Ejecting Media after an

Error”.

8) The LCD will display

“Media Released”. The

media gate will lower, allowing the erased

media to exit the degaussing chamber via

the Exit Slide located on the right side of the

degausser.

9) The degausser’s internal counter will advance

one count and display the total number of

media degaussed for the current session.