AT&T AUDIX Networking 585-300-903 User Manual
Page 195

AUDIX Network Testing
14-13
_
______________________________________________________________________________________
_
______________________________________________________________________________________
_
______________________________________________________________________________________
Step 1D: Testing Remote Dedicated RS-232 Connections
This test involves a path similar to Figure 14-11, Remote Connection Test (RS-232 Direct).
1. Go to the
system : translation : machine : audix/amis/call delivery
form.
Set machine name to the name of the other AUDIX system. Press
ENTER
. The other AUDIX
system’s machine profile should be displayed. If it is not displayed, it has not been assigned. Go to
Chapter 13, AUDIX System Administration, and create the remote system profile.
2. The network connection channel (or channel) should be set to the number of the channel that is
cabled to the other AUDIX system. In Figure 14-11, the AUDIX system 1 RS-232 channel 5 is a
switched connection and channel 6 is cabled to AUDIX system 2. The AUDIX system 2 profile at
AUDIX system 1 should have a
6
in the network connection channel field.
3. The network data phone number (or dial string) should be blank. Press
CHANGE or RUN
if any
changes were made.
4. Go to the
maintenance : network
form. Make sure the channel to be tested is idle.
5. Go
to select test and enter 1.
6. Go
to machine name and enter the name of the other AUDIX system. Press
CHANGE or RUN
. Wait
for the result. If the test is not successful, check the
system : log
and/or go to Flowcharts For
Troubleshooting the Network.