AUDIX Network Testing

14-13

_

______________________________________________________________________________________

_

______________________________________________________________________________________

_

______________________________________________________________________________________

Step 1D: Testing Remote Dedicated RS-232 Connections

This test involves a path similar to Figure 14-11, Remote Connection Test (RS-232 Direct).

1. Go to the

system : translation : machine : audix/amis/call delivery

form.

Set machine name to the name of the other AUDIX system. Press

ENTER

. The other AUDIX

system’s machine profile should be displayed. If it is not displayed, it has not been assigned. Go to
Chapter 13, AUDIX System Administration, and create the remote system profile.

2. The network connection channel (or channel) should be set to the number of the channel that is

cabled to the other AUDIX system. In Figure 14-11, the AUDIX system 1 RS-232 channel 5 is a
switched connection and channel 6 is cabled to AUDIX system 2. The AUDIX system 2 profile at
AUDIX system 1 should have a

6

in the network connection channel field.

3. The network data phone number (or dial string) should be blank. Press

CHANGE or RUN

if any

changes were made.

4. Go to the

maintenance : network

form. Make sure the channel to be tested is idle.

5. Go

to select test and enter 1.

6. Go

to machine name and enter the name of the other AUDIX system. Press

CHANGE or RUN

. Wait

for the result. If the test is not successful, check the

system : log

and/or go to Flowcharts For

Troubleshooting the Network.