Set a ah & info v h, Start pause mode, Mxts 70 – CTEK MXTS 70 User Manual

Page 3: Normal agm gel agm power ca/ca supply amp

Advertising
background image

EN • 5

EN

INDICATION LAMPS:

START/PAUSE LAMP

Indicates that charging has not started or has been interrupted.

Press START/PAUSE-button to start/resume.

POWER LAMP

Indicates that mains supply is connected.

ERROR LAMP

Indicates that a fault has occurred.

Se ERROR CODES for description.

Press START/PAUSE-button to clear error and interrupt charging.

TEMPERATURE SENSOR LAMP

Indicates that the temperature sensor is activated.

Voltage is automatically adjusted to optimize charge at

ambient temperature.

REDUCED CURRENT LAMP

Indicates that the maximum current is limited.

SET

A

Ah & info

V

h

1

2

3

4

5

6

7

8

NORMAL

AGM

GEL

AGM

POWER

Ca/Ca

SUPPLY

Amp

12V/70A
24V/35A

MXTS 70

START

PAUSE

MODE

INDICATION LAMPS, DISPLAyS

AND ERRORCODES

SET

A

Ah & info

V

h

1

2

3

4

5

6

7

8

NORMAL

AGM

GEL

AGM

POWER

Ca/Ca

SUPPLY

Amp

12V/70A
24V/35A

MXTS 70

START

PAUSE

MODE

SETTINGS BEFORE START:

DISPLAy (V)

Indicates voltage set

Options: 12/24 Volts

DISPLAy (A)

Indicates current set

Options: 70/50/40/30/20 A in 12V setting

Options: 35/25/20/15/10 A in 24V setting

70A/35A could only be selected for Supply program.

For Normal-, Ca/Ca-, AGM/GEL- and AGM Power-program maximum

current is 50A/25A.

DISPLAy (h)

Indicates which parameter to set

Options: U/A/

DISPLAy (Ah & info)

Displays error codes

REAL TIME INDICATION DURING ChARGING:

DISPLAy (V)

Displays output voltage

DISPLAy (A)

Displays output current

DISPLAy (h)

Alt. 1. Displays total elapsed charging time (minutes/hours)

Alt. 2. Displays time elapsed until error occured

DISPLAy (Ah & info)

Alt.1. Displays total charge delivered since start (minutes/hours)

Alt.2. Displays error codes together with ERROR lamp

ERROR CODES:

E01

REVERSE POLARITy

Connect the charger according to “CONNECT THE CABLES”

E02

OVER VOLTAGE

Battery voltage to high for the chosen charging program, check

battery voltage.

E03

TIME OUT STEP 1: DESULPhATION

Restart the charger. If charging is still being interrupted the bat-

tery is seriously sulphated and may need to be replaced.

E04

TIME OUT STEP 2: SOFT START

Restart the charger. If charging is still being interrupted the battery

can not accept charge and may need to be replaced.

E05

TIME OUT STEP 5: ANALySE

Restart the charger. If charging is still being interrupted the bat-

tery can not keep charge and may need to be replaced.

E06

BATTERy OVERhEATED

The battery is too hot to charge. The battery is damaged and

may need to be replaced.

E07

LOW BATTERy VOLTAGE IN SUPPLy PROGRAM

Battery voltage too low or too large consumers connected. Check

if 12V battery connected in 24V battery setting or disconnect

large consumers.

E08

hIGh CURRENT IN SUPPLy PROGRAM

Check if clamps are short circuited or connected reversed polarity.

E99

OVER VOLTAGE PROTECTION

If battery voltage is below 17V the ERROR lamp is lit when 24V

setting has been selected.

Alt 1. Press START/PAUSE button to charge with 12V setting.

To set the parameters for customized charging proceed with

“CHARGING” step 5 to 8

Alt 2. Press INCREASE or DECREASE button to change to

24V setting. Press START/PAUSE button to resume. To set the

parameters for customized charging proceed with “CHARGING”

step 5 to 8.

SET

A

Ah & info

V

h

1

2

3

4

5

6

7

8

NORMAL

AGM

GEL

AGM

POWER

Ca/Ca

SUPPLY

Amp

12V/70A
24V/35A

MXTS 70

START

PAUSE

MODE

SET

A

Ah & info

V

h

1

2

3

4

5

6

7

8

NORMAL

AGM

GEL

AGM

POWER

Ca/Ca

SUPPLY

Amp

12V/70A
24V/35A

MXTS 70

START

PAUSE

MODE

10-70

12/24

E01-E99

E01

SET

A

Ah & info

V

h

1

2

3

4

5

6

7

8

NORMAL

AGM

GEL

AGM

POWER

Ca/Ca

SUPPLY

Amp

12V/70A
24V/35A

MXTS 70

START

PAUSE

MODE

SET

A

Ah & info

V

h

1

2

3

4

5

6

7

8

NORMAL

AGM

GEL

AGM

POWER

Ca/Ca

SUPPLY

Amp

12V/70A
24V/35A

MXTS 70

START

PAUSE

MODE

SET

A

Ah & info

V

h

1

2

3

4

5

6

7

8

NORMAL

AGM

GEL

AGM

POWER

Ca/Ca

SUPPLY

Amp

12V/70A
24V/35A

MXTS 70

START

PAUSE

MODE

SET

A

Ah & info

V

h

1

2

3

4

5

6

7

8

NORMAL

AGM

GEL

AGM

POWER

Ca/Ca

SUPPLY

Amp

12V/70A
24V/35A

MXTS 70

START

PAUSE

MODE

20015126D Manual MXTS70, All languages, Print file 003.indd 5

2011-10-11 13:01:28

Advertising