Battery types and settings – CTEK MXS 4003 User Manual

Page 5

Advertising
background image

5

EN

BATTERY TYPES AND SETTINGS

The MULTI XS 4003 model offer several alternative settings to suit specific charging

needs and required functionality. The following recommendations should only be

regarded as guidelines. Please observe the battery manufacturer recommendations

in the event of uncertainty.

Settings are made by pressing the “MODE-button” and stepping forward one press

at a time until the required mode is reached, the button is then released. After about

two seconds the charger activates the selected mode. The selected mode setting will

be restored next time the charger is connected.

The table explains the different modes:

Mode

Battery

size

(Ah)

Explanation

1.2–14

Mode 14.4V/0.8A

This mode shall be used for batteries smaller than 14Ah.

14–140

Mode 14.4V/4A

Normal mode for wet batteries, MF and for most GEL

batteries.

14–140

Mode 14.7V/4A

This mode is recommended for charging batteries at

temperatures lower than +5°C. It is also recommended for

many AGM batteries. This setting is not recommended for

maintenance charging when the temperature temporarily

exceeds +5°C. Here we recommend the 14.4V/4A or

14.4V/0.8A mode.

RECOND

14–140

This mode is used to recover deeply discharged batteries

where you could expect a stratified acid (high acid weight

in the bottom, low on top). This problem arises primarily in

open vented batteries, i.e. not Gel and AGM. Use this step

with care, because the high voltage may cause some water

loss in the battery. Contact the battery supplier if you are

uncertain. 15.8V is normally no problem for electronics in

12V systems but consult your supplier when in doubt. The

service life of lamps drops at higher voltages. Maximum

effect and minimum risk for electronics is achieved by

charging a disconnected battery in this step.

Advertising