CTI Products EXB-IP Ethernet System Extender User Manual

Page 13

Advertising
background image

CTI Products, Inc.

EXB-IP User Guide

Introduction

13

HTTP Page Security Note

The EXB-IP and EXB-IP 8000 units have an HTTP page that shows the status of the unit, including the IP
parameters programmed into it and its On-Line / Off-Line status. This is useful for system troubleshooting.

This feature is turned off at the factory by default.

If your network security policies mandate against this type of data being accessible through HTTP pages, verify
that the HTTP page by setting Switch 2 Down and resetting the unit. For further security, restrict physical
access to the unit and the networks to which it connects.

If your network security policies allow you to use HTTP pages and you desire to have the HTTP page turned on
for troubleshooting, set Switch 2 Up and reset the unit.

Note: Some networks (including Motorola Solutions, Inc. Radio Network Infrastructure - RNI) have routers
and or firewalls that restrict HTTP traffic between certain network segments. If you have such a system, you
may not be able to open the HTTP page from a different IP subnet, even if you have the HTTP page enabled on
the EXB-IP unit.

Advertising