Appendix e. troubleshooting, Table e1, Table e2 – CTI Products EXB-IP Ethernet System Extender User Manual

Page 47: Table e3, Ppendix, Roubleshooting

Advertising
background image

CTI Products, Inc.

EXB-IP User Guide

Appendix E - Troubleshooting

47

A

PPENDIX

E.

T

ROUBLESHOOTING

Table E1

If the PWR LED . . .

REASON

CORRECTIVE ACTION

Is always illuminated.

Normal operation indicating that EXB

module is receiving proper DC input
power.

Go to next Table.

Does not illuminate.

EXB module is not receiving DC input

power.

Check for proper voltage at “DC IN”

connector (10-32VDC).

Table E2

If the ERR LED . . .

REASON

CORRECTIVE ACTION

Is always off.

Normal operation indicating no error

condition was detected.

Go to next Table.

Occasionally blinks on, then

off.

Normal operation when “CSVC” button or

“RSVC” button is pressed.

Go to next Table.

Flashes slowly, at a rate of

once every 2 seconds.

The Router Neurons are unconfigured.

Use LonScrpt or NODEUTIL to change the

mode/state to ‘Configured’ and ‘On-
line’,
or
Use SETRTR2 –F to configure the
router to Factory default conditions
(Repeater Mode).

Flashes quickly, at a rate of

once every second.

The Control Neuron Processor detects

missing IP address information.

Use EXB-IP Config to update the IP address

parameters. (See Installation section
for instructions.)

Is always illuminated.

Router module, or Control Neuron

Processor, or Microprocessor is not
functioning.

Call CTI Products, Customer Support

(+1-513-595-5900), to arrange to
return module for evaluation/repair.

Table E3

If the ETH TX LED (on

local EXB-IP module)
. . .

REASON

CORRECTIVE ACTION

Occasionally blinks on, then

off.

Normal operation indicating a message

packet has been transmitted from the
Ethernet port.

Go to next Table.

Does not illuminate when

“RSVC” button on local
EXB-IP module is
pressed.

Ethernet port is not terminated correctly to

the IP network.

a.

Verify that OPTION switch positions 7
and 8 are set correctly for the Ethernet
connector being used. See
I

NSTALLATION

section.

b.

Verify that the cable from EXB-IP
module Ethernet port is terminated
correctly to IP network. Check the
‘connection’ LED that is found near
each port on most IP interconnect
devices.

c.

Verify that the correct cross or straight-
through cable is being used. See
“Appendix F. IP Addresses”.

Advertising