Dip switch "c, Warning – Controlled Products Systems Group RAM3000 User Manual

Page 15

Advertising
background image

13

www.ramsetinc.com

RAMSET

R

AM 3

000 U

L

- 3100 U

L

- 3200 U

L

Dip Switch "C" 2; Not in use at this time.

Leave in the ‘Off’ position.

Dip Switch "C" 6; “OPEN DELAY”

One second delay on the opening of the gate.

Dip Switch "C" 5; “CLOSE DELAY”

One second delay on the closing of the gate.

DIP SWITCH "C"

Dip Switch "C" 1; “SECURE CLOSE”

Sw. Function:

OFF Normal

Operation

ON

When power is lost, then regained, control board

checks status of the gate. If open and safety

devices are cleared, gate will close automatically.

Dip Switch "C" 3; “RADIO CYCLE”

Sw. Function:

OFF Normal Operation - gate only opens and closes on

the limit switches. If the gate is in travel then it will

always open.

ON

Cycle mode - gate opens and closes on the limit

switches, but if in travel, then it will stop with a first

command and reverse with a second command.

Dip Switch "C" 8; “SLAVE MODE” Master/Slave configuration

Sw. Function:

OFF Master mode - single gate operation. All peripheral

devices are to be connected to the master operator.

ON

Slave mode - used to synchronize operation between

two gates. Commands are received from the master

through a 3-wire, shielded cable.

(Not provided with unit).

Dip Switch "C" 7; “LEFT / RIGHT”

Sw. Function:

OFF Left hand installations - All operators come factory

set for left hand operation.

ON

Right hand installations - Reverses motor & limit

switches without moving any wires.

Dip Switch "C" 4; “ONE PASS”

Sw. Function:

OFF Normal Operation - fully opens and closes

ON

One pass mode - The gate will open until “the

reversing loop” is initially activated and then cleared,

the gate will then close. If the “reversing loop” is

then activated again, before the gate is fully closed,

the gate will stop until the “reversing loop” is cleared,

then continue to close.

WARNING:

When installing or servicing an operator, make sure switch
"C" 1 is ‘Off’. If switch "C" 1 is ‘On’, the gate will move when
power is applied and severe injury may occur.