WIRE BOARD CONNECTIONS

JP7 -

Master/Slave plug:

1) A

2

)

B 3) Common 4) 5 VDC

5) 24 VAC.

Used to synchronize the operation between two

gates. A three-wire, Shielded cable is needed to run
from the A, B, & Common (JP7) of the master P.C.B.
to the A, B, & Common (JP7) of the slave P.C.B.

JP6 -

Battery back-up plug:

1) A

2

)

B 3) Common 4) 5 VDC

5) 24 VAC.

Use this plug when using optional battery

back-up system, Ramset Keypad.

1) 24 VDC.

5) Relay Common

2) 24 VAC

6) Fully Closed-N.C.

3) 5 VDC

7-8) Constant/Prewarn

4) Fully Open-N.O.

9-10) E.R.D. Alarm.

If E.R.D. is triggered twice before reaching a

limit, 24 VDC is supplied to sound an alarm (included
with operator).

JP10 -

Loop Inputs:

1-2

)

Reverse 3-4) Exit 5-6) Phantom

Use with ILD-24 Loop wires

should be connected to this plug.

JP3 -

3 Button:

1) Close 2) Stop 3) Open 4) Common

Used with a 3-button station to open,

stop, and close the gate. The open and close are
normally open connections and the stop is a nor-
mally closed connection, remove jumper wire when
connecting 3 button station. Common and stop are
also used with a photo eye used to protect the back-
plane of the operators.

JP9 -

Input Power:

1,2) 24 VAC power.

Connection from external transformer to
power Control Board.

JP4, JP5 & JP8

-

Reverse, Exit & Phantom

Sensor:

Used with the Ramset ILD-24 plug-in loop detector.

The Loop wires should be connected into the
“LOOP INPUTS” plug.

Fully Open N.O. (works with relay common) -

Relay rated at 125 VAC, 2 amps. Normally open
connection. Open contact occurs until the open
limit is triggered. When the open limit is
triggered, a closed contact occurs.

Relay Common - Relay rated at 125 VAC, 2 amps.

The common of the Fully Closed N.C. relay and
the Fully Open N.O. relay.

Fully Closed N.C. (works with relay common) -

Relay rated at 125 VAC, 2 amps. Normally
closed connection. Closed contact occurs until
the closed limit is triggered. When the closed
limit is triggered, an open contact occurs.

JP2 -

Relay Connections: