TERMINAL STRIP CONNECTIONS

Terminal # 1 - COMMON:

Low voltage common.

Terminal # 2 - REV LOOP:

Stops the gate from closing. If the gate is open,
it holds the gate open. If the gate is closing, it
stops and reopens the gate. If the gate is closed,
the gate will remain closed. The function can be
altered with Dip Switch "C" 4 (see “Dip Switch
Configuration”). Used with loop detectors, photo
eyes, safety edges…etc. Becomes active with a
closed contact to common.

Terminal # 3 - CLOSE:

Closes the gate. Used with three button stations
or pushbuttons. Becomes active with a closed
contact to common.

Terminal # 4 - FIREBOX:

Opens the gate. Used with fire department key
switches & controls. Opens with closed contact
to common. Closes immediately when closed
contact on common is removed.

Terminal # 5 - EXIT:

Opens the gate. Used with loop detectors, photo
eyes, keypads, phone entry systems, three-but-
ton stations…etc. Becomes active with a closed
contact to common.

Terminal # 6 - PHANTOM:

Keeps the gate open when the open limit switch
is activated. Used with loop detectors. Becomes
active with a closed contact to common.

Terminal # 7 - RADIO:

Operation depends on dip switch "C" 3 (See “Dip
Switch Configuration”). Used with an RF receiver
or pushbutton. Becomes active with a closed
contact to common.

Terminal # 8 - EDGE:

When triggered the gate will stop. The gate
will remain stopped until the detector is cleared.
Once the detector is cleared, the operator will
resume normal operation. If triggered twice
before reaching a limit switch, the alarm will
sound for 6 minutes and the control board will not

accept any commands. After the 6 minutes the
24 VDC is removed from the alarm connection
and the board resets to normal operation.

Terminal # 9 and 10 - LIMIT 1 & LIMIT 2:

Direction depends on Dip Switch "C" 7 (See “Dip
Switch Configuration”). Stops the motor from
moving in one direction. These wires are preset
in factory and should not be moved. Becomes
active with a closed contact to common.

Terminal # 11 and 12 - COMMON:

Low voltage common.

Terminal # 13 - +24 VAC:

Provides 24 VAC for peripheral accessories.

Terminal # 14 and 15 - MAG (-) & MAG (+):

Supplies 24 VDC to a Magnetic Lock when the
gate is closing or closed. If gate is opening or
opened, then no power is supplied. Leave open
if not used.

Terminal # 16 - M BRAKE:

Used ONLY on the Ram 50 Operator. If while the
gate is closed someone or something tries to
manually open the gate without a proper signal
(keypad, exit loop, radio signal…), the motor will
lock up for 6 minutes. After the 6 minutes, the
operator will then secure close the gate.

Terminal # 17 and 18 - MOTOR 1 & MOTOR 2:

Supplies power to the motor. Direction depends
on Dip Switch "C" 7 (see “Dip Switch Configura-
tion”). These wires are preset and connected in
the factory and should not be moved.

Terminal # 19 and 20 - AC HOT & NEUTRAL:

110 VAC or 220 VAC to power the operator.
Voltage is predetermined at factory and cannot
be changed by the installer or technician.