background image

4-2

D0536 Rev. B

StrongArmPark DC: Programming & Operations Manual

www.hysecurity.com

o

vervIeW

of

tHe

s

mart

dC C

ontroller

The Smart DC Controller uses LED’s to indicate active inputs when AC power is present. For operators that use

only DC power, you can push a button to show the active inputs. This SHOW LEDS button is at the bottom left

corner near the EMERG OPEN input.

On a new operator no active inputs should appear until external accessories and wiring are attached. If any inputs

are active before connecting external wiring, refer to Troubleshooting.

COM

COM

COM

COM

COM

COM

COM
COM

STOP
OPEN

RADIO

CLOSE

OPEN

OPEN

PARTIAL

EYE

OPEN

EYE

CLOSE

EXIT

LOOP
BLOCK

EXIT

IN OBS

LOOP

OUT OBS

LOOP

CENTER

LOOP
EDGE
EYE

COM
+ 24 V
EMERG

OPEN

SHOW

LEDs

RADIO OPTIONS

EDGE +24V OPE

N COM

DUAL GATE

COM

B

A

U

SE

R2

COM NO

DC

COMMON

TERMINALS

USER RELAY 1

Electro-mechanical

24VDC

24VDC

24VAC

24VAC

12VDC

12VDC

Multi-colored LED indicates power and gate status:
GREEN indicates AC power and RUN mode.
YELLOW indicates Menu mode.
RED indicates Alert, Fault, or Error.

Not lit means AC power is lost. Pressing the
SHOW LED’s button indicates which inputs,
if any, are active.

Red LED heart beat.

Press button to light
active inputs.

USER RELAY Solid State

USB Port

RS-485

COMMUNICATION