Dc c, Verview, Mart – Controlled Products Systems Group STRONGARMPARK DC 10 User Manual
Page 42: Ontroller

4-2
D0536 Rev. B
StrongArmPark DC: Programming & Operations Manual
www.hysecurity.com
o
vervIeW
of
tHe
s
mart
dC C
ontroller
The Smart DC Controller uses LED’s to indicate active inputs when AC power is present. For operators that use
only DC power, you can push a button to show the active inputs. This SHOW LEDS button is at the bottom left
corner near the EMERG OPEN input.
On a new operator no active inputs should appear until external accessories and wiring are attached. If any inputs
are active before connecting external wiring, refer to Troubleshooting.
COM
COM
COM
COM
COM
COM
COM
COM
STOP
OPEN
RADIO
CLOSE
OPEN
OPEN
PARTIAL
EYE
OPEN
EYE
CLOSE
EXIT
LOOP
BLOCK
EXIT
IN OBS
LOOP
OUT OBS
LOOP
CENTER
LOOP
EDGE
EYE
COM
+ 24 V
EMERG
OPEN
SHOW
LEDs
RADIO OPTIONS
EDGE +24V OPE
N COM
DUAL GATE
COM
B
A
U
SE
R2
COM NO
DC
COMMON
TERMINALS
USER RELAY 1
Electro-mechanical
24VDC
24VDC
24VAC
24VAC
12VDC
12VDC
Multi-colored LED indicates power and gate status:
GREEN indicates AC power and RUN mode.
YELLOW indicates Menu mode.
RED indicates Alert, Fault, or Error.
Not lit means AC power is lost. Pressing the
SHOW LED’s button indicates which inputs,
if any, are active.
Red LED heart beat.
Press button to light
active inputs.
USER RELAY Solid State
USB Port
RS-485