Controlled Products Systems Group STRONGARMPARK DC 10 User Manual

Page 45

Advertising
background image

www.hysecurity.com

SDC Inputs & Wiring

D0536 Rev. B

4-5

Label

SDC Terminal

Wire Connections

Commonly used for...

EYE OPEN Eye Open

Spare input for StrongArmPark DC
only. N.O. input for SlideSmart DC &
SwingSmart DC. Connection for Photo
Eye Open direction. Can be changed
to a monitored Normally Closed (N.C.)
contact through the Installer Menu

Non-contact entrapment sensors.

EYE
CLOSE

Photo Eye Close
direction

N.O. input. Connection for Photo Eye
Close direction. Can be changed to
a monitored Normally Closed (N.C.)
contact through the Installer Menu.

Non-contact entrapment sensors.

EXIT
LOOP

Free Exit Vehicle
Detector

N.O. input. Connection for free exit
vehicle detector.

Vehicle detector, box type
connections for free exit loop.

BLOCK
EXIT

Block Free Exit
vehicle detector or
Close Timer

N.O. input. Free Exit is only disabled if
Close Limit Switch is tripped.

Installer menu enabled. See DT 0

If the gate is partially opened,
the Free Exit detector will trigger
the gate to open fully. The input
can be converted in the Installer
Menu to alternately disable the
Close Timer.

IN OBS
LOOP

Inside Obstruction/
Arming Vehicle
Detector

N.O. input. Inside reversing loop.

Vehicle detector, box type
connections inside reversing loop

OUT OBS
LOOP

Outside Obstruc-
tion/Arming Vehicle
Detector

N.O. input. Outside reversing loop.

Vehicle detector, box type con-
nections outside reversing loop

CENTER
LOOP

Center Loop
(Shadow) Vehicle
Detector

N.O. input. Center Loop for
StrongArmPark DC. Shadow function
used for Swing gates only.

Vehicle detector, box type con-
nections. Shadow function for
swing gates, reset function for
barrier arm gates.

EDGE

Edge Sensor

N.O. input. One input works for both
directions of travel. It can be changed to
N.C. contact through the Installer Menu.

Gate edge, entrapment device
sensor connections. One input
works for both travel directions.

EYE
COM

Photo Eye Common When the Photo Eye Open and

Photo Eye Closed common wires are
connected to this terminal, the photo
eyes energize only when the motor runs.

Photo eye connections.

Use these terminals to preserve
battery power.

+ 24

+24V DC

24VDC power.

Convenient 24VDC power for
photo eyes or the Emergency
Open input.

EMERG
OPEN

Emergency Open
(Fire Dept.Open) **

N.O. input.

The Emergency Open must be
enabled via the Installer Menu.
It is energized by connecting to
the +24V terminal above it. The
EMERG OPEN overrides photo
eye & edge sensor commands.

* Do not connect an external control to the STOP or OPEN inputs unless the controls are located in clear view
of the entire gate area. Use the RADIO OPEN input or RADIO OPTIONS spade connections for all out-of-sight
controls, such as a telephone entry or radio operated controls.

**The Fire Department Open control must be keyed or guarded so that it can only be used by authorized
personnel.

SDC Inputs

COM

COM

COM

COM

COM

COM

COM
COM

STOP
OPEN

RADIO

CLOSE

OPEN

OPEN

PARTIAL

EYE

OPEN

EYE

CLOSE

EXIT

LOOP
BLOCK

EXIT

IN OBS

LOOP

OUT OBS

LOOP

CENTER

LOOP
EDGE
EYE

COM
+ 24 V
EMERG

OPEN

SHOW

LEDs

24VDC

24VDC

24VAC

24VAC

12VDC

12VDC