Reference

D0536 Rev. B

7-1

CAUTION

Wires are attached
to the physical stop
bracket. Do NOT sever
the wires or hang the
bracket by the wires.

12

3

Using a 1/2-inch socket wrench, remove four
fasteners securing the physical stop bracket.
(Do NOT break the wire connections.) Hang the
bracket from the side of the chassis, as shown.

12

4

Remove the drive belt. Use a 9/16-inch socket
wrench to loosen (do NOT remove) the 4 bolts
securing the motor to the motor plate.

12

2

If the drive belt cover is in place, use a phillips
head screwdriver to remove two screws that
secure it to the motor plate. Set the drive belt
cover and fasteners aside.

CAUTION

12

5

Wires are attached
to the motor!

• Disconnect the 2 motor

wire leads from the
wire harness inside the
chassis.

• Disconnect the blue

connector wire from the
Smart DC Controller
and pull it out of the
control box.

12

1

Remove the front access panel. (Keys come with
the operator.)
Use a phillips head screwdriver to remove the
plastic cover from the control box.

12

6

Top cover

Drive belt cover

Drive belt

Loosen, DO NOT remove, 4 bolts
on motor cover plate

Physical stop bracket

Two phillips head screws

Control box:
Smart DC
Controller
access

Set screws

Nylon bolts for
breakaway bracket

Motor.
See
CAUTION

ContInued

....

Turn the page for more information.

Disconnect the
2 motor wires.

Disconnect wire
leads before
removing the motor

Remove 4 bolts and lift the motor plate
assembly from the chassis. Set it aside.

Physical stop bracket

Reference

H

andIng

C

Hange

All StrongArmPark DC operators are shipped from the factory in a left handing configuration unless specified

otherwise. If you need to change the StrongArmPark DC14 handing at the site, you will need to:

• Release spring tension

• Swap locations of the spring’s eyebolt and spacer

on the physical stop lever

• Retention the spring

NOTE: If changing the handing on StrongArmPark DC10,
follow steps 1 and 10.