Dc b, Attery, Eplacement – Controlled Products Systems Group STRONGARMPARK DC 10 User Manual

Page 70

Advertising
background image

6-4

D0536 Rev. B

StrongArmPark DC: Programming & Operations Manual

www.hysecurity.com

5. With your finger, apply light outward pressure to the drive

belt. If it is properly tensioned, it should only move about

1/16 to 1/8-inch (1.6 to 3.2cm).

6. To replace or re-tension the drive belt. Loosen the four

motor bracket nuts and move the motor accordingly.

7. Retighten the motor bracket nuts.
8. Replace the drive belt cover and top cover.
9. Turn the AC and DC power switches ON. This cycles

power which allows the operator to search for the target

magnet and “relearn” its limits.
NOTE: Be aware that the arm will cycle open, and then

close, as it relearns its limits. If you don’t cycle the power,

the operator will not “relearn” its limits and will not

operate properly.

dC B

atterY

r

eplaCement

HySecurity provides a one year warranty from the date of

shipment for all batteries supplied with the StrongArmPark DC operator.

Display indicators of a low battery include:

• LOW BATTERY or DEAD BATTERY appears on the Smart DC Controller display which may or may not be indicative

of normal discharge.

• ALERT 18 CHANGE BATTERY appears on the Smart DC Controller display. The operator emits an audible chirp

every minute to indicate a problem exists.

• AP (#) AC LOSS appears on the Smart DC Controller display. Gate operation is affected by AC power loss

depending on customer preferences and the configuration set by the installer in the AP (#) AC LOSS User Menu.

Symptoms of a low battery may include:

• Gate remains locked in the open position

• Gate remains locked in the closed position

• Gate opens five seconds after AC power loss and locks open

CAUTION

Before replacing the batteries, turn off all power switches. Use only AGM batteries as replacements (8Ah -
MX002008). The batteries supplied in the StrongArmpark DC operator are state-of-the-art AGM batteries.
Do NOT use flooded cell batteries as damage may occur to the unit. Wear protective clothing while working
with batteries.

The two 8Ah batteries are accessible within the operator on a tray next to the gear box.

LTR

1/16 to 1/8-inches
(1.6 to 3.2 mm)

Motor bracket nuts

Pulley