Switch examples continued – Impulse 2403 User Manual

Page 10

Advertising
background image

Configuration

Sealevel Systems SeaPORT+4 Page

7

Switch Examples Continued


Port 4 Port 3 Port 2 Port 1

Figure 3: Electrical Interface Configuration


Port 1 : RS-232

The corresponding shunt is in the 232 position. The switches will have
no effect.


Port 2 : RS-485 two wire communication with no echo.

The corresponding shunt is in the 422/485 position. Switches 485 2,
NE 2, and Port 2 L, L, T, PU, and PD are all in the ON position.


Port 3 : RS-422 with 120 ohm termination.

The corresponding shunt is in the 422/485 position. Switches 485 3,
NE 3, and Port 2 L, L, PU, and PD are all in the OFF position, T is in
the ON position.


Port 4 : RS-485 two wire communication with echo.

The corresponding shunt is in the 422/485 position. Switches 485 4,
and Port 2 L, L, T, PU, and PD are all in the ON position, NE 4 is in
the OFF position.

RS 232

RS 232

RS 232

RS 232

RS 422/485

RS 422/485

RS 422/485

RS 422/485

Port 3
L
L
T
PU
PD

ON

12

3
4
5
6
7

8

OF
F

91

0

Port 4
L
L
T
PU
PD

ON

12

3
4
5
6
7

8

OF
F

91

0

Port 1
L
L
T
PU
PD

Port 2
L
L
T
PU
PD

E1

E4

E3

E2

E5

E6

E7

E8

SW2

SW4

Advertising