A b
calculates rates for
inputs A (I1) & B (I2)
A OnLy
calculates rate for
input A (I1)
bAtCH
calculates rate (I3),
total (I1), grand total for batch-
ing (I2), input A
A Atot
calculates rate (I1)
and total for input A (I2)
A btot
calculates rate for
input A (I1) and total for input
B (I2)
A + b
calculates rate for
input A (I2), rate for input B
(I3), and sum of both inputs
(I1)
A - b
calculates rate for
input A (I2), rate for input B
(I3), and difference of both
inputs (I1)
A . b
calculates rate for
input A (I2), rate for input B
(I3), and product of both in-
puts (I1)
A / b
calculates rate for
input A (I2), rate for input B
(I3), and ratio of both inputs
(I1)
A/b-1
calculates rate for
input A (I2), rate for input B
(I3), and draw of both inputs
(I1)
A b
calculates period
for inputs A (I1) & B (I2)
A OnLy
calculates period
for input A (I1)
10.
SETUP MENU
VALUE SELECT KEY
MENU KEY
DIGIT SELECT KEY
DUAL CHANNEL SIGNAL CONDITIONER
InPut
Input signal type
rAtE
Frequency or rate
Note:
(I1), (I2), and (I3) are display
items 1, 2, and 3. The value
that is displayed may be se-
lected via front panel
pushbutton.
Basic counter:
A b, A Only
Extended counter:
All items shown
PEriod
Period
Basic counter:
A b, A Only
Extended counter:
All items shown
-10-