DIGIT SELECT KEY
VALUE SELECT KEY
MENU KEY
-18-
SourcE
Source of alarm operation
(only enabled if relay output
installed)
ALSEt
Alarm Operation Setup
(only enabled if relay output
installed)
0
Filtered item
1
Item 1
2
Item 2
3
Item 3
0
Filtered item
1
Item 1
2
Item 2
3
Item 3
0
relay 1 on, relay2 on
1
relay 1 off, relay2 on
2
relay 1 on, relay2 off
3
relay 1 off, relay2 off
0
AL1 nonlatching
AL2 nonlatching
1
AL1 latching
AL2 nonlatching
2
AL1 nonlatching
AL2 latching
3
AL1 latching
AL2 latching
0
AL1 active high
AL2 active high
1
AL1 active low
AL2 active high
2
AL1 disabled
AL2 active high
3
AL1 active high
AL2 active low
4
AL1 active low
AL2 active low
5
AL1 disabled
AL2 active low
6
AL1 active high
AL2 disabled
7
AL1 active low
AL2 disabled
8
AL1 disabled
AL2 disabled
00
Compare Alarm 1 to:
00
Compare Alarm 2 to:
00000
Relay output status when
alarm active (On or off)
00000
Relay output status when
alarm active (Latching or
nonlatching)
00000
00000
Alarm status
If deviation > 0, then:
active high = energizes out-
side deviation band
active low = energizes inside
deviation band