Venue Narrowband Receiver

Hardware Installation

Receiver Modules

VRS and VRT receiver modules can be mixed in the

same chassis, For ratio diversity operation, both mod­

ules in the pair must be on the same frequency block

and positioned in the assembly in keeping with the

OPTI-BLEND labeling on top of the chassis housing.

Front panel

All modules must be within the frequency passband of

the host assembly. Frequency blocks are marked on the

receiver module and chassis housings.

Installing Receiver Modules

1. Turn the power off.

The receiver modules interface with the main as­

sembly through multi-pin connectors on either side

of the chassis. Insert the module straight down and

then slide it toward the main housing to insert the

connector pins. The module should sit flush against

the side of the housing.

Retaining

clips

Caution: Make sure the connectors align

correctly. Do not force the module onto the tab.

Excessive force may damage the connectors.

2. Align the ridge on the retaining clip with the slot in

the chassis and press the clip downward until the

ridge snaps into the slot in the side panel.

Removing Receiver Modules

1. Turn the power off.

2. Remove the retaining clip by pressing on it side­

ways to release it from the slot in the side panel.

Then pull upward to remove it.

3. Pull outward on the module to release the connec­

tor and then lift it upward out of the chassis. Holes

in the underside of the chassis allow you to grip the

module on the top and bottom.

Rack Installation

1. Mount the receiver(s) in the desired rack location(s).

There are no special ventilation requirements.

2. Connect the antennas or coaxial cables to the

antenna input connectors (outermost) on the rear

panel.

Note: The frequency bandwidth of the antennas

must cover the range of the modules in use.

3. For multiple unit installations, a “loop thru” is avail­

able to feed two or three receivers from a single

antenna pair. Connect coaxial cables from the mul­

ticoupler outputs on the first receiver to the antenna

inputs on the next receiver in the stack.

The outermost connectors are the inputs connected

to the antennas on the first unit in the stack. The

innermost connectors are the outputs that feed the

next assembly in the rack.

10.5-18VDC

RS-232

6

5

4

LINK 2

3

2

1

IN

USB

IN

OUT

OUT

ANTENNA A

LINK 1

LINK 3

1

3

2

1

3

2

1

3

2

ANTENNA B

1

3

2

1

3

2

1

3

2

10.5-18VDC

RS-232

6

5

4

LINK 2

3

2

1

IN

USB

IN

OUT

OUT

ANTENNA A

LINK 1

LINK 3

1

3

2

1

3

2

1

3

2

ANTENNA B

1

3

2

1

3

2

1

3

2

LINK 3

LINK 2

LINK 1

4. Plug the power supply into a suitable outlet and

plug the power connector into the Power Input Jack.

5. Turn down the audio inputs on all the externally

connected equipment, then connect cables to the

appropriate Audio Output XLR Jacks.

LECTROSONICS, INC.