Mcu recovery from interrupted firmware update – Lectrosonics SPNTWB User Manual

Page 13

Advertising
background image

Installation and Startup Guide

Rio Rancho, NM

13

5) Click on Next in the control panel and another page

will open, allowing you to select the device to be up-

dated. Highlight the device and click Next to proceed.

6) The next page allows you to select the update file.

Use the “Browse” button to point at the firmware update

file and click

Next to continue.

Browse button

7) Review the information displayed and click on

Start

Update.

8) Do not disturb the USB cable connection during the

update process. The firmware update takes up to 15

minutes to complete. Be sure the computer does not

go into hibernation or sleep mode during the update

process.

NOTE: If the procedure is interrupted, see the

next section on recovery

9) When the update is complete, click

Finish to exit the

Update Wizard.
10) Cycle the power on the processor to restart using

the updated firmware.

MCU Recovery from Interrupted Firmware

Update Procedure

If instructed to do so by Lectrosonics Customer Sup-

port, the firmware in a non-functioning unit can be

restored.
Launch the Control Panel program. After the panel

opens, click on

Connect->Update Firmware...

In the lower part of the screen is a check box that is

used only for the recovery process. When the box is

checked, the instructions will change to describe the

recovery procedure.

Recovery check box

Follow the on-screen prompts to return the unit to nor-

mal operation.