Mandatory Settings

Set up the system in the

Switched Mode in the Net-

work Config screen in Dante Controller. Once every-

thing is set up and audio is flowing to and from the

network, a second network and gigabit switch can be

added and the mode can be changed to

Redundant.

Connect an SPNDNT Dante port to the computer either

directly or through a gigabit switch.

Dante Primary Port

Connect the PC to the

Primary Port in case the mode

had previously been set to Redundant. Confirm that

the 1G and LINK/ACT LEDs next to the Dante port are

flickering.
Launch the Dante Controller software. A brief splash

screen appears, followed by the Network View/Routing

screen. The serial number of the connected processor

will appear in the bars labeled

Receivers and Trans-

mitters.

Processor name and

serial number appear in

the blue bars

Double click on either blue

bar to open the Device View

dialogue box

Double click on the processor name/serial number to

open the Device View dialog box. Under the

Network

Config tab, select Switched.

Select

Network

Config

Select

Switched

Select the

Device Config tab, then set the sample

rate to 48k. The sample rate MUST be 48k so the DSP

(filters, etc.) will operate as they should.

Device Config Tab

Select 48k Sample Rate

Latency under the same tab can be adjusted depend-

ing upon the number of switches in the network.
The other tabs in the Device View dialog box are used

to rename channels and check the status of several

parameters.
Consult the

Help menu for details and explanations of

Dante Controller software.