Using switched and redundant modes, Ethernet switch – Lectrosonics SPNDNT User Manual

Page 15

Advertising
background image

Installation and Quick Start Guide

Rio Rancho, NM

15

100-240V

50/60Hz 30W

ASPEN PORTS

ETHERNET

RS-232

SPN 1624

OUTPUTS

INPUTS

OUTPUTS

INPUTS

GND

+5V

PROG IN

PROG

OUT

GND

PROG IN

+5V

PROG

OUT

Adaptive Proportional Gain Mixing

US Patent 5,414,776

S/N LABEL

DATECODE

Secondary network for redundancy

RS-232 ports for external control system

Network Audio Transport

Supplied ASPEN cables

CAT-5 or better

cables

CAT-6 cable

Ethernet switch

OR

(optional)

To front panel

USB port

Using Switched and Redundant Modes

NOTE: See page 11 for instructions on

selecting the mode using Dante Controller

software.

Set processors to the

Switched mode for setup.

In the

Switched mode, the Primary and Sec-

ondary ports can be connected in any combi-

nation since there is an ethernet switch in the

hardware.
In the

Redundant mode, the Primary ports on

all processors must be connected to the first net-

work and the

Secondary ports on all processors

must be connected to the second network.
After all connections and settings are completed

and the system is passing audio through the net-

work, connect the second network and set the

processors to the

Redundant mode.

These connections

are for setup and

control with ASPEN

Control Panel

software.

Advertising