General setup – Liquid Controls LCR 600 Setup & Op User Manual
Page 23

23
general Setup
Pulse Output edge:
(LB)
c
Determines the signal of the calibrated pulse output waveform. Some external components function on rising
pulse edges, others on falling pulse edges. Refer to the technical manual of the specific component to determine
requirements.
Pulse Output Freq:
(fE)
c
Determines the frequency of the pulse output per unit of measure sent by the Auxiliary Output 3 on terminal 42 of the
J12 terminal block. Common components include external counters and injection systems. The default value is 1.
general Setup 2
Ticket Header Text:
(fE)
c - u (Lines 11 and 12 c only)
Supplies 12 lines where you can enter text for the ticket header.
Every delivery ticket printed by the LCR 600 will print this text at
the top of every ticket.
l - locked
u - unlocked
c - Weights & measures calibration
p - Stop/pause
f - factory
Security clearance
fE - field Edit Box
LB - List Box
field type