PAT-LS-12270 Series Fluid Section Manual

Rev. 01/2012

Page | 24

Special Outlet Body Assembly PAT-LS-1001-GL:

1.

Install O-ring (O-E-133) into the Outlet Body (PAT-LS-1001-GL)


2.

Install Glutton Seal (PAT-LS-1024) and Spacer (PAT-LS-1023) into the Outlet
Body (PAT-LS-1001-GL)


3.

Install Bushing (PAT-LS-1005 –GL) and Seals (PAT-LS-1016) into solvent cup.

4.

Firmly tighten the Solvent cup into the Outlet Body (PAT-LS-1001-GL)


5.

Screw item Seal Tool (PAT-GL-TOOL-1) on to Upper rod

6.

Push shaft downward through Glutton Seal using a hard rubber or plastic mallet
to form seal.

















7.

Remove the Seal Tool (PAT-GL-TOOL-1) from the Upper Rod

8.

Screw Piston to bottom of the Upper Rod.

9.

Connect the Outlet Body to the Inlet Body and torque bolts as noted below in
Chapter 5.