Preparation and priming of “new” system – Magnum Venus Plastech PATRIOT 1-1_4 PAT-LS-12270 User Manual

Page 30

Advertising
background image

PAT-LS-12270 Series Fluid Section Manual

Rev. 01/2012

Page | 30

PREPARATION AND PRIMING OF “NEW” SYSTEM


1.

Be sure all air regulators are turned completely to the left, shutting off air to the
components.


2.

Slowly open main air.

3.

Seat Pro Gun Packing: Tighten the gun valve rod packing nuts until they are
snug. IMPORTANT: Activate the gun trigger 8 - 10 times then tighten the
packing nuts again.
Repeat this tightening procedure 3 times to make sure the
gun valve rod packing is tight

.


4.

Prime empty catalyst line:
a. Disengage catalyst pump
b. Open ball valve on catalyst manifold (if applicable)
c. Eliminate air pockets by manually hand pumping the catalyst 5-10 short

strokes (2-3 in.). After eliminating air pockets, and while continuing to hand
pump, close ball valve on catalyst manifold.

d. Pull and hold trigger on gun while hand pumping catalyst pump with short

strokes until there is a solid, steady catalyst flow from the head of the gun.
This will ensure that all air is purged from the line. Release trigger.

e. Continue to hand pump the catalyst pump with short strokes until catalyst pump

is fully primed and pressurized (generally within 5 additional strokes or less).

NOTE: Do NOT engage slave pump until material pump has been primed.


5.

Material Pump: (be sure catalyst pump is disengaged) Place a container or
bucket under ball valve located at the bottom of the resin filter assembly to catch
material while priming. Open ball valve. Slowly bring up pressure on material
pump regulator just enough to allow pump to stroke up and down evenly. After a
smooth flow of material is flowing from the valve, turn regulator off and close the
valve.


6.

Remove mix chamber and turbulent mixer from front of gun (Pro Gun). Pull
trigger on gun and allow gun to hang above waste container. Slowly bring up
pump pressure again to allow material to flow out of gun. Release trigger to
close gun. Pump will cycle until it is fully primed and then will stall out.


7.

Engage slave pump.

Advertising