Module 4 - 1769-IF8 : 8 point analogue input module

Terminal Signal description

V IN 0+ Air preparation pressure sensor (1-5V : 0-10 bar)

V/I IN 0-

I IN 0+

ANLG COM

V IN 1+ Catal sensor (0-5V)

V/I IN 1-

I IN 1+

ANLG COM

V IN 2+ ITV pressure

V/I IN 2-

I IN 2+

ANLG COM

V IN 3+ Mixing Head Pressure (0-10V : 0 - 10 bar)

V/I IN 3-

I IN 3+

ANLG COM

V IN 4+

V/I IN 4-

I IN 4+

Mould Pressure (4-20mA : 0-2 bar absolute)

ANLG COM

V IN 5+

V/I IN 5-

I IN 5+

Ambient temperature (4-20mA)

ANLG COM

V IN 6+

V/I IN 6-

I IN 6+

ANLG COM

V IN 7+

V/I IN 7-

I IN 7+

ANLG COM