Master Appliance UT-100Si Ultratorch Soldering Iron_Heat Tool User Manual

Page 5

Advertising
background image

1. Set gas control lever to 3 and move On/Off lever to “ON”. In cold conditions, move gas lever

higher, in warm, lower.

2. Push ignition button all the way down slowly, holding in down position for 3 seconds after it

clicks. You may hear a whistling sound.

3. When catalyst inside of exhaust opening glows red, slowly release button.

4. If unit did not ignite, repeat.

5. To turn off, move On/Off lever to “OFF” position until it clicks.
Temperature can be changed by adjusting gas control lever.

Ignition Instructions

Use as a Soldering Iron or Heat Tool

All models come with the soldering tip pre-installed. To change tips, unscrew knurled nut,

drop out tip and drop in replacement tip.

As a soldering iron, heat conducts into tip. Touch tip to

work surface and apply solder. Use proper tip for type

of work being performed. Make sure hot air exhaust

points away from work surface.

As a heat tool, heated gas flows from the end of the

heat tip. Use the heated gas to heat, dry or shrink as

necessary. Tip temperatures can be varied by adjust-

ing the gas control lever.

To Replace Ejector

The ejector is where the

air/fuel mixture takes place.

Occasionally it may be

necessary to replace due

to clogging.
Unscrew the knurled nut and

remove the tip and tip hous-

ing. Disconnect ignition wire

by gently pulling lead wire

down and away from ignition

tube. Insert spanner wrench

into small hole in the ejec-

tor. While holding spanner

wrench stationary, loosen

locking hex nut above

ejector by using open end

wrench and turning counter

clockwise. Use spanner

wrench to remove ejector.

Replace ejector and tighten.

Mount burner by turning

clockwise onto ejector until

light tension is felt. Align insu-

lation tube in a straight line

with ignition wire. Tighten hex

nut with open end wrench

while holding ejector in place

with spanner wrench. Insert

lead wire into insulation tube.

Push ignition button to con-

firm sparking. Replace tip

and tip housing.

Advertising