Table 4-6. kf3 setup selections, 2 of 2 – Micromod Micro-DCI: 53MC5000 PLC AND PRINTER INTERFACES User Manual
Page 43

Table 4-6. KF3 Setup Selections
Option
Description
Range
Set Value
3
RS-232 Baud Rate
300
600
1200
2400
4800
9600
19200
03
06
12
24
48
96
19
96
4
Parity
No Parity
Even Parity
00
01
00
5
DF1 Protocol
Full-Duplex
Half-Duplex Local
Half-Duplex Remote
00
01
02
00
6
Error Detection
BCC
CRC
00
01
00
7
Modem Handshake
Disabled
Enabled
00
01
00
8
Duplicate Message Detection
Disabled
Enabled
00
01
00
9
Sub-Menu Selections:
0 - Maximum Token Holder Address
1 - Token Hold Factor
2 - DF1 Retries
3 - DF1 ACK Timeout
4 - CTS-to-Transmit Delay
5 - End of Message-to-RTS Off
6 - Half-Duplex Master Address
7 - Group Number
01-31
01-10
00-10
01-50
00-99
00-99
00-77
00-77
31
01
00
01
00
00
10
00
4.7.2 ALLEN-BRADLEY KF2 COMMUNICATION OPTION SWITCHES
The Allen-Bradley KF2 communications option switch selections are provided in Figure 4-5. It is
recommended these same settings be used whenever possible.
2 of 2
Section 4. Allen-Bradley Mode
ALLEN