Maintenance and Care

7.6

Recovery tank

1 Recovery tank
2 Drain hose
3 Float Shut off
4 Tank lid

7.6.1 Empty recovery tank
Clean recovery tank (Fig. 13/1) at daily
intervals, as required or upon acoustic
signal (increased vacuum motor
speed).
1. Take machine to appropriate area for
draining.
2. Park machine such that drain hose
reaches a drain aperture in the floor.

3. Switch off machine.

Observe the legal provisions
and the local regulations for
disposal of detergents.

4. Take drain hose (Fig. 13/2) from
holder and empty recovery tank
completely.

7.6.2 Clean recovery tank
Clean recovery tank at daily intervals or
as required.
1. Empty recovery tank per 7.6.1

2. Open tank lid (Fig.13/4) of the
recovery tank.
3. Take drain hose (Fig. 13/2) from
holder and empty recovery tank
completely.
4. Remove remaining dirt by rinsing
tank and hose with clean water.

Fig.13

7.6.3 Clean Suction Filter
Check suction filter (Fig. 13/3) at daily
intervals and clean if required. The
suction filter can be easily removed by
pulling downward.

1

3

2

4