Changing fluid types – MotorVac TRANSTECH IV User Manual
Page 15
[email protected] www.motorvac.com
Changing Fluid Types
Follow these steps if it is necessary to completely empty the clean fluid tank in order to
change to another type of fluid.
1. Install an open adapter in the clean hose coupler. Install hose into a capture container.
2. Connect power cord to a 12 volt DC source. Press the MODE button until both the In-Line and Manual
LED’s are on.
3. Press & hold the FILL button. The pump will operate until the FILL button is released.
4. Tip the unit slightly backwards to let the fluid flow toward the back of the tank for complete evacuation.
5. Pressing the STOP button for five seconds will reset the unit.
Follow these steps if it is necessary to completely empty the dirty fluid tank.
1. Connect the power cord to a 12 volt DC source.
2. Direct the waste hose to a suitable disposal container. Open the ball valve on the end of the waste hose.
3. If the EMPTY WASTE LED is on, press the EMPTY WASTE button. The unit will automatically pump out
the dirty fluid until the fluid level stops at the switch in the bottom of the tank. The EMPTY WASTE LED
will go off.
4. Press and hold the EMPTY WASTE button for 5 seconds to enter MANUAL WASTE mode. Unit will
beep. Release the button. The EMPTY WASTE LED will flash.
5. Press and hold the EMPTY WASTE button. The pump will operate until the EMPTY WASTE button is
released.
6. Tip the unit slightly backwards to let the fluid flow toward the back of the tank for complete evacuation.
7. Pressing the STOP button for five seconds will reset the unit.
12