Nitek IPCOAX16 User Manual

Nitek, Model ipcoax16, Installation and operation manual

Advertising
background image

Model IPCOAX16

16 Ch. Ethernet over Coax Surge Protector

Installation and

Operation Manual

Rev 052912

NITEK

®

Europe Office:
De Schans 19-21 2a, 8231 KA Lelystad
The Netherlands
Tel: +31(0)320-230005
Fax: +31(0)320-282186
E-mail: [email protected]
WWW.NITEK.NL

USA Office:
5410 Newport Drive, Rolling Meadows, IL 60008
Phone: (800) 528-4343
Fax: (847) 259-1300
E-mail: [email protected]
WWW.NITEK.NET

68-016-0104

Specifications

Size

2

RU


Connection Video

Standard female BNC


Clamping Voltage

58v (on all channels)

Impedance

50 and 75 ohms


Temperature

-40°C

to

+85°C

Installation

The IPCOAX16 must be properly installed to insure maximum protection. The function of the IPCOAX16 is to

allow a surge to be routed to ground and to clamp the protected equipment video inputs to a minimum voltage.

There are three key points to remember when installing the IPCOAX16. First, provide a low impedance

connection between the IPCOAX16 and your protected equipment. This is best done by keeping the PROTECTED
coax cable connections as short as possible, ideally less than 3 feet, and using a coax with a good braid.

Second, the system should use a single ground point. Connect the grounding stud of the IPCOAX16 to a single

ground point. A single ground point is a proper building ground to which equipment grounds are connected. Ideally,
the protected equipment should be isolated from ground. If the IPCOAX16 and the protected equipment are both
grounded you will provide a parallel path to ground and a portion of the surge current can flow through that path.
Additionally, AC power line protectors should be used to complete your surge protection strategy.
Finally,

the

UNPROTECTED cables and wires should not be crossed with the PROTECTED cables and wires.

Crossing cables could provide a path for surge currents to bypass the DVRCOAX16 protection circuits.

Description

The IPCOAX16 is designed to provide 16 channels of
Ethernet over Coax surge protection, as well as
supporting PoE+ devices. It is cost-effective and ideally
suited for protecting multiple devices. The IPCOAX16
is rack mountable in a standard 19” rack. It installs in
minutes and provides a single easy access point for
grounding. The 16 channels use 58 volt solid-state
clamping for unmatched protection.

NITEK

IN

OUT

1

2

3

4

6

5

7

8

9

10

11

12

13

14

15

16

R

Surge Protection System

IN

OUT

1

2

3

4

6

5

7

8

9

10

11

12

13

14

15

16

115 / 230 VAC

50/60Hz

640 Watts Max

8A 250V

RISK OF FIRE -

REPLACE FUSE

AS MARKED

CAUTION

MADE IN U.S.A.

RoHS

C O M P L I A N T

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

LAN 1

LAN 2

ET1500

IP Camera

IP Camera

ET1500

Advertising