Troubleshooting


After completing installation, if the units are not operating properly, check each step at each unit in order.

1) If the Power LED is off verify the unit’s power connections and verify that the power source is on an active cir-

cuit.

2) If the link status LED does not stop blinking, verify that the coax cable has been properly installed and make

sure Control unit’s link Type LED is “OFF” and that Remote unit’s link Type LED is “ON”.

3) If the Activity LED is “OFF” verify you have power to the camera and good connections to the RJ45 connectors.

4) If the activity LED is “ON” and the link status LED is “ON” and there is no picture, verify camera IP address and

monitoring IP address are proper and refresh the monitor. Directly attach the camera through a short patch cable
directly to NVR/IP network. Verify that camera and monitor program are properly functioning.