0 parameter setting – Nova-Tech WBW Series User Manual

Page 19

Advertising
background image

© Adam Equipment Company 2009

17

13.0 PARAMETER SETTING


This section allows the user to access the parameters for customising the
scale. The parameters are split into 2 groups-

1. Check weighing Parameters
2. Scale Parameters

In the following sections use the

[Limit] key to scroll through the options, the

[Tare] key to accept the option and the [Zero] key to return to weighing.
Wherever numeric values are required to be entered, use the

[Limit] and

[Unit] keys to increment the flashing digits as explained in section 4.1.


13.1 CHECK WEIGHING PARAMETERS

To enter this section press and hold the

[Limit] key for 4 seconds. You will

be asked for the password if the current check-weighing password is
anything other than “0000”. See the parameter “F4 PS” in this section. Enter
the correct password using the numeric entry method as mentioned in
section 4.1. If the password is “0000” it will go directly to “F1 LLK”.

Parameter Description

Options

Default setting

F1 LLk

Limit Lock will prevent a normal
user from changing the check
weighing limits. To change the
limits, this parameter must be
disabled by setting it to off or the
user must enter the password.

on
oFF

oFF

F2 LEd

Setting the LED

on
oFF

on

F3 bEP

This parameter sets the Beeper to
off or on. If set to on, the beeper
can further be set to sound when
the weighing result is within or
outside the check-weighing limits.

bP oFF

- Off

bP inL

- Within

limits

bP otL

- Outside

limits (>20d)

bP inL

F4 PS

This parameter allows setting of a
new Check weighing password,
If the old parameter is “0000” enter
the new password twice when “

P1

_ _ _

“ & “

P2 _ _ _ _

” are displayed.

When complete, it will display

To be entered
manually.

0000

Advertising