Tubing assembly installation and lubrication – Nova-Tech Chem-Tech XP Series User Manual

Page 12

Advertising
background image

REV. L PN J63031

- 12-

6.2 Tubing Assembly Installation and Lubrication

WARNING:

When using the pump to load tubing the rocker switch must be in

the Off (“O”) position to prevent accidental motor starting. Caution must be used
to keep fingers away from rotating parts.











Figure 8: Pump Head w/ Rotor Assembly Removed

NOTE: Lubrication of rotor assembly should be performed at least once a year
(residential service). Clean front and rear rotor bearings and surfaces with a
clean shop cloth (See head assembly illustration at the end of this manual).
Lubricate with a PTFE thickened, medium viscosity, synthetic grease intended for
plastic parts. Ref. Grease Kit (P/N J30257) – see Figure 8.

1. Reinstall the rotor assembly by aligning the cross in the rotor to the drive shaft
cross and fully insert into pump head.

2. Use the 100% button and align the rotor assembly as shown in Figure 9a.

Figure 9a: Rotor Alignment at Start of Tube Installation

Note position of
tube and rotor’s
cut-away guide

Lube all roller (3)
and bearing
surfaces (2)

P/N NC82XX3LP1-XXXXX

ROLLER ASSEMBLY

Advertising