Pulse timer pumps, Dry contact input pumps, General operation – Nova-Tech Chem-Tech XP Series User Manual

Page 9: General

Advertising
background image

REV. L PN J63031

- 9-

5.3. Pulse Timer Pumps

If the pump was purchased with the pulse
timer mode the pumps rate control knob
will adjust the pumps run time per pulse
input received. The timer does not
accumulate pulses that are received
during the run time. Available pulse timers
are 0.1 to 1 second, 0.2 to 10 seconds
and 1.2 to 60 seconds.

The pump is also provided with a 10 foot
(3 meter) signal cable with two bare leads.
The input is a dry contact, compatible with
contacting head type water meters and
the input has no polarity. No voltage is

permitted on the input signal.

5.4. Dry Contact Input Pumps

If the pump was purchased with the Dry Contact Input mode, the pump will be
activated and deactivated by this dry contact input. The pump is provided with
a 10 foot (3 meters) signal cable with two bare leads. The input is a dry
contact, intended to be connected to a dry contact switch, and the input has
no polarity. No voltage is permitted on the input signal. The pump will
activate and run for the full time that the switch is closed, and deactivate
when the switch opens.

5.5. General Operation

DANGER:

DO NOT ATTEMPT TO FEED CHEMICALS WITHOUT FIRST

CONSULTING YOUR CHEMICAL FEEDER DEALER OR CHEMICAL
SUPPLIER. To avoid running out of chemical, follow a regular schedule of
monitoring chemical supply.

CAUTION: Inspect peristaltic tubing frequently and replace when deterioration
becomes apparent. Peristaltic tubing will eventually wear and break if neglected.
This occurrence will cause chemical spillage and a potential for personal injury or
damage to equipment. Always refer to chemical manufacturers
recommendations with regards to safety and handling of hazardous or corrosive
chemicals. Always wear protective clothing and safety glasses when working
near chemical feed systems.

WARNING:

Do not expose the pump or tubing to pressure exceeding the

pressure rating on the pump nameplate.

1. Make sure the rocker switch is in the off/neutral position...
2. Fill the chemical tank with the chemical to be fed.