7. Fit the diaphragm head back into place on the
pump body.

8. Torque the six diaphragm head bolts to the fol-
lowing inch pounds in a crisscross pattern:

(1) Liquid End Size SG5 and SG6 metallic and

non-metallic head bolts to 90 inch pounds.

(2) Liquid End Size SG7 non-metallic head

bolts to 125 inch pounds.

(3) Liquid End Size SG7 metallic head bolts to

250 inch pounds.

4. Add oil to pump, following directions given in
“Initial Start-up” in Section 3.