General precautions for all pumps – Nova-Tech LMI Series G - SG Metering Pump User Manual

Page 3

Advertising
background image


The following precautions should be taken when working with

all metering pumps.

Please read this section carefully prior to installation.

Protective Clothing

ALWAYS wear protective clothing, face shield, safety glasses and gloves when working on or near your
metering pump. Additional precautions should be taken depending on the solution being pumped. Refer
to Material Safety Data Sheets for the solution being pumped.

Hearing Protection

!

It is recommended that hearing protection be used if the pump is in an environment where the time-
weighted average sound level (TWA) of 85 decibels is exceeded. (as measured on the A scale -- slow
response)

Electrical Safety

!

• Remove power and ensure that it remains off while maintaining pump.

DO NOT FORGET TO CONNECT THE PUMP TO EARTH

• Electric protection of the motor (Thermal protection or by means of fuses) is to correspond to

the rated current indicated on the motor data plate.

Liquid Compatibility

!

Verify if the materials of construction of the wetted components of your pump are recommended for the
solution (chemical) to be pumped.

Pumps Water “Primed”

!

All pumps are tested with water at the factory. If your process solution is not compatible with water, flush
the Pump Head Assembly with an appropriate solution before introducing the process solution

Plumbing and Electrical Connections

!

Always adhere to your local plumbing and electrical codes.

Line Depressurization

!

To reduce the risk of chemical contact during disassembly or maintenance, the suction and discharge
lines should be depressurized before servicing.

Over Pressure Protection

!

To ensure safe operation of the system it is recommended that some type of safety/pressure-relief valve
be installed to protect the piping and other system components from damage due to over-pressure.

Lifting

!

This manual should be used as a guide only - Follow your company’s recommended lifting procedures. It
is not intended to replace or take precedence over recommendations, policies and procedures judged as

safe due to the local environment than what is contained herein.

!

Use lifting equipment that is rated for the weight of the equipment to be lifted.

ii

General Precautions For All Pumps

Advertising