Maintenance, Important, Periodic maintenance – Poweramp POWERSTOP SERIES User Manual

Page 20

Advertising
background image

18

4111-0014 — July 2013

MAINTENANCE

Periodic Maintenance

To ensure normal operation of the dock leveler and
vehicle restraint, use only aircraft hydraulic fluid
designed to meet or exceed military specification
MIL-H-5606 G. It is recommended that the following
hydraulic fluids be used:

• ULTRA-VIS-HVI-15
• Aero Shell Fluid 4 or Fluid 41
• Mobile Aero HFA Mil-HS606A or Aero HF
• Texaco Aircraft Hydraulic Oil 15 or 5606
• Exxon Univis J13

These fluid brands can be mixed together. Mixing with
fluids that do not meet or exceed MIL-L-5606 may
damage the equipment and WILL void warranty. Use
of hydraulic fluids with equivalent specifications to
those listed here are acceptable.

A— Scissors Assembly
B— Hook Weldment
C— Rear Vertical Track

D— Rear Track Assist Spring
E— Platform Hinge Area
F— Bottom Slide Track

G — Bellows
H— Main Springs
J— Pin

K— E-Clip
L —Bearing

IMPORTANT

Use of fluids that do not have equivalent
specifications to those in the following list will result
in abnormal operation of the dock leveler and
voiding of warranty.

Before performing any maintenance under the
dock leveler or vehicale restraint lock the electrical
power source in OFF position using an approved
locking device.

Failure to follow these instructions may result in
serious personal injury or death.

A

B

C

E

D

K

F

L

H

L

G

J

Advertising